Any air gap between the insulation and the wall on the warm side of the cavity causes thermal looping.
Cavity wall insulation beads problems.
Cracking to render spalled blown bricks etc.
Probably the biggest cavity wall insulation problem is driving rain if you live in a an area which is exposed to driving winds then you are at a higher risk of moisture penetration.
Thermal looping happens when there s an air gap between the insulation boards and the inner leaf of blockwork this leads to heat getting drawn from the inside of the house into the cavity.
The polystyrene used for cwi is in the form of virgin pre formed bead which is usually combined with a binding agent or adhesive at the time of injection.
Most people don t understand that problems with cavity wall insulation can also be down to defects in the building itself.
Your home is exposed to severe levels of wind driven rain zones three or four in our map below your home is located in an unsheltered position eg not protected by trees or other buildings.
Until recently dampness problems caused by cavity wall insulation have not generally occured in houses where the insulation was built in from new although this is now changing and the first acounts of dampness caused by built in cavity batts are starting to come in.
The gaps that naturally occur between the spherical beads allow any water to drain down freely to the ground rather than across to create damp problems on inside walls.
Benefits of blown bead.
The process seems simple drill into the outer wall inject a fibre or bead insulation into the cavity make good the holes sit back and enjoy reduced energy bills.
Independent research has confirmed that cavity wall insulation is a very reliable process.
Damp could occur in properties as a result of cavity wall insulation if there is a combination of these factors.
If your wall is in poor condition i e.
If you live in zone 1 or 2 on the map below then you are at less risk.
The structure of the installed blown bead allows the cavity to retain the ability to breathe as intended with the cavity wall insulation in place.
Problems are therefore extremely rare but if they do occur ciga has the expertise to ensure that they are swiftly rectified.
Plus driving rain can get through a well maintained facing brick wall.
In some cases the damp and mould resulting from cwi can cause health problems or exacerbate existing conditions particularly respiratory conditions.
Damp problems caused by cavity wall insulation.
Polystyrene beads are produced to a specified size and density which remains unaltered during the.